Data Loggers
| Specifications for specific thermocouple types | ||||||
Type |
K |
N |
R |
S |
B |
J |
Measuring range |
-100°C*
1370°C -148°F 2498°F |
-100°C*
1300°C -148°F 2372°F |
-0°C
1760°C -32°F 3200°F |
-0°C
1760°C -32°F 3200°F |
55°C
1815°C 131°F 3300°F |
0°C
800°C 32°F 1472°F |
Accuracy |
±
0.3°C** / 0.5°F |
±
0.4°C** / 0.7°F |
±1.0°C at 200°C ±1.8°F at 392°F ±0.7°C at 1000°C ±1.3°F at 1832°F |
±1.0°C at 200°C ±1.8°F at 392°F ±0.8°C at 1000°C ±1.4°F at 1832°F |
±3°C at 400°C |
±0.2°C
/± 0.4°F |
Resolution |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
*'Using sampling interval >0.8 seconds over range shown
**Contact Datapaq for accuracy at -100°C to -190°C
| Specifications for specific logger types | ||||
| Normal operating temperature | High operating temperature | |||
| Model number* | TP2086 | TP2016 | TP2186 | TP2116 |
| No. of channels | 8 | 10 | 8 | 10 |
| Memory (data points) | 130,000 | 130,000 | 130,000 | 130,000 |
| Max. operating temp. | 70°C / 158°F | 70°C / 158°F | 110°C / 230°F | 110°C / 230°F |
| Battery type | NiMH rechargeable | NiMH rechargeable | VHT Lithium | VHT Lithium |
| Max. battery life between charges** | 340 hours | 340 hours | 250 hours | 250 hours |
| Sampling interval: | ||||
No
telemetry |
0.1 sec 50 mins | 0.1 sec 50 mins | 0.1 sec 50 mins | 0.1 sec 50 mins |
Hardwired
telemetry |
1 sec 50 mins | 1 sec 50 mins | 1 sec 50 mins | 1 sec 50 mins |
RF
telemetry |
n/a | 2 secs 50 mins | n/a | 3 secs 50 mins |
| Max. operating pressure at 20°C / 68°F | 20 bar / 290 psi | 20 bar / 290 psi | 20 bar / 290 psi | 20 bar / 290 psi |
| Min. operating pressure at 20°C / 68°F | 10-5millibar | 10-5millibar | 10-5millibar | 10-5millibar |
| *
Model number shown is for type K thermocouples only, other types have different
model numbers ** Max. battery life depends on sampling interval, operating temperature and use of RF telemetry |
||||
| Case size (all logger types) | ||
| Length | 200 mm / 7.87" | |
| Width | 98 mm / 3.86" | |
| Height | 20 mm / 0.79" | |
| General operating specifications | ||
| Logger start by: | Manual (button), Temperature (rising or falling), or Time | |
| Programmable events: | Up to 8 sampling interval changes possible per run, trigger by rising or falling temperature after first event | |
| Hot data protection: | By non-volatile memory, and software warning if reset attempted before download | |
| Communication: | Via USB or RS 232 for lap top computers | |
| Logger reset: | Possible after download by start button (uses same run parameters) | |
|
The Q18 data logger has been designed using the latest miniaturised electronic packaging technology, enabling us to combine speed of readings, superb accuracy and high resolution all in one versatile unit.
|
|
||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
| Specifications for specific thermocouple types | ||||||
| Type | K | N | R | S | J | T |
| Measuring Range | -100 to 1370 °C -148 to 2498 °F |
-100 to 1300 °C -148 to 2372 °F |
50 to 1760 °C 122 to 3200 °F |
50 to 1760 °C 122 to 3200 °F |
0 to 800 °C 32 to 1472 °F |
-100 to 400 °C -148 to 752 °F |
| Accuracy | ± 0.3°C | ± 0.4°C | ± 1.1°C | ± 1.1°C | ± 0.3°C | ± 0.3°C |
| ± 0.5°F | ± 0.7°F | ± 2.0°F | ± 2.0°F | ± 0.5°F | ± 0.5°F | |
| Resolution | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C |
| 0.2 °F | 0.2 °F | 0.2 °F | 0.2 °F | 0.2 °F | 0.2 °F | |
| External Logger Specification |
![]() |
| Part number: | XD0012 |
| Number of channels: | 12 channels, sockets will accept standard thermocouple plugs |
| LED’s: | 2 x battery (low and charging) 2 x status |
| Thermocouple combinations: | Combination of 3 types |
| Examples: | 10 type N + 2 type S, |
| 9 type K + 3 type R, etc. | |
| Specify at time of ordering | |
| Maximum operating temperature range: | 0 to 55°C / 32 to 131 °F |
| Humidity operating range: | 0 to 85% RH non-condensing |
| Battery type: | NiMH Re-chargeable |
| Battery life: | 60 hours |
| Power input: | 12V DC from universal 100/230V AC |
| Communication: | Via USB |
| Sampling interval range: | 1 second to 50 minutes |
| Case size: | Height (without computer rest) = 60mm / 2.36 “ |
| Height (with computer rest) = 80mm / 3.14 “ | |
| Width (overall) = 330mm / 12.99 “ | |
| Depth (including handle) = 340mm / 13.39 “ | |
| Weight: | 6.5kg / 14.33 lbs |
| Case IP rating: | IP50 |
| Logger start: | Manual (start button);Time; Temperature Trigger (rise/fall on any thermocouple) |
| Insight software: | v6.0 and above |
| Hot data protection: | Non-volatile memory or software warning if reset attempted before download |
| Telemetry: | Hardwired only |
|
|
![]() |
Interconnecting leads Interconnecting leads connect between the plug on the vacuum furnace and the data logger. Leads are available in all types of thermocouples. |
||
![]() |
CS1201/X* Interconnecting Lead Miniature socket CS1200/X* Interconnecting Lead Standard socket
|